Clean steam condensate recovery
Clean steam condensate is a valuable raw material - in many applications, the condensate still contains a significant amount of residual heat and has not been contaminated during the process. It is therefore ideal feedwater for steam generation. The Lautenschläger condensate recovery system collects condensate from your steam consumers, stores it in an insulated tank, and pumps it to the steam generators as needed. If the amount of recovered condensate is insufficient to serve as feedwater for steam generation, the system automatically supplements it with fresh feedwater from your water treatment system. The available condensate and the thermal energy it contains are fully recovered, and fresh feedwater is used only when necessary.

Lautenschläger Condensate Recovery for optimized sustainability and cost-effectiveness
Technical Data
| max. condensate capacity [l/h] | Condensate temperature [°C] | Storage temperature [°C] | Tank volume [l] |
|---|---|---|---|
| 200 | < 140 | adjustable < 95 | 100 |
| Pump capacity [l/min] | Pump pressure [m] | Power supply | Dimensions [mm] |
|---|---|---|---|
| 50 | adjustable 1 - 15 | 1/N/PE ~ 230 V | 1750 x 550 x 780 (HxWxD) |
When designing a pure steam supply system, the requirements are entirely different from those for a process or heating steam supply. In addition to material selection and purity requirements, the process characteristics of the steam consumers often result in additional specifications. For example, pure steam for autoclaves in laboratories or in industrial and pharmaceutical applications must not be superheated, nor may it contain excessive moisture. Furthermore, it should be as free as possible of non-condensable gases. Our brochure “Pure steam supply lines for steam sterilization“ was written with the aim of describing the requirements for pure steam supply systems in steam sterilization technology and identifying possible technical solutions.
Steam used in sterilization processes should be saturated steam that is free of impurities and contains no non-condensable gases. Impurities in the sterilization steam enter the autoclave and are transferred to the products. This can damage or contaminate your products, cause unwanted deposits to form, or even endanger human life. These residues in the steam can originate from the feedwater, the steam boiler, or the steam lines. Our brochure provides many valuable tips for optimizing your steam supply system.